Considerations To Know About high performance liquid chromatography
Considerations To Know About high performance liquid chromatography
Blog Article
Because the stationary section is polar, the mobile stage is a nonpolar or a reasonably polar solvent. The mix of the polar stationary section plus a nonpolar cell phase is called normal- period chromatography
The column measurement is similar. The column is filled with silica particles which can be modified for making them non-polar. That is done by attaching extended hydrocarbon chains (eight–18 C atoms) to its surface area.
전자를 '고정상', 후자를 '이동상'이라 부르며 크로마토그래피에서는 분석자는 고정상과 이동상의 조합에 의해 분석물의 분리를 제어할 수 있게 됩니다.따라서 분석물, 고정상, 이동상, 세 가지 특성의 이해가 크로마트그래피에서 매우 중요합니다.
, which permits us to explore a broad array of cell phases with only seven experiments. We begin by changing the amount of acetonitrile inside the mobile stage to create the best possible separation in just the desired Assessment time.
Various other detectors have been used in HPLC. Measuring a adjust during the mobile section’s refractive index is analogous to checking the cell phase’s thermal conductivity in fuel chromatography. A refractive index detector is nearly common, responding to almost all compounds, but has a relatively poor detection limit of 0.
-hydroxybenzoic acid—on a nonpolar C18 column utilizing an aqueous buffer of acetic acid and sodium acetate as the mobile section. The retention instances for these weak acids are shorter click here when utilizing a much less acidic cell section for the reason that Every single solute is current within an anionic, weak foundation variety that is significantly less soluble from the nonpolar stationary stage.
If you prefer to to reuse any articles, in print or on-line, from ChemistryViews.org, be sure to Speak to us to start with for permission and check with our authorization advice prior to creating your request.
-hydroxybenzoic acid elutes a lot more gradually. Though we will solve absolutely both of these solutes making use of cellular period that may be sixteen% v/v acetonitrile, we can't resolve them In case the cell period is 10% tetrahydrofuran.
加温することが多かったため「オーブン、ヒーター」と称されるが、現在では周辺気温より低温にするための冷却機能が付いている装置も多い。また、周辺気温付近で使用する場合にも冷却機能は一定の効果がある。
Retention periods: Time it's going to take for each analyte to reach the detector, supplying a characteristic fingerprint for identification.
If we swap from applying acetonitrile to tetrahydrofuran, one example is, we learn that benzoic acid elutes a lot more rapidly Which p
In loop injection, an outlined quantity of sample is loaded into a loop. The injector valve then switches, directing the sample onto The top on the column, where by it's carried through the cellular period.
Stream level: Flow rate adjustment read more impacts how speedily analytes shift through the column. An optimum circulation fee balances separation performance with Examination time.
The injector is positioned once the pump to introduce the sample into the mobile section. Syringes are one of the most common sample injectors. In the auto-injector, injection on the sample occurs automatically with the predetermined time.